SciELO - Scientific Electronic Library Online

 
vol.12 issue6Non invasive evaluation of central venous pressure using echocardiography in the intensive care: Specific features of patients with right ventricular enlargement and chronic exacerbated pulmonary diseaseThe evaluation of neopterin and antioxidants in long lasting asthma author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista Portuguesa de Pneumologia

Print version ISSN 0873-2159

Rev Port Pneumol vol.12 no.6 Lisboa Nov. 2006

 

Comparação dos valores da capacidade pulmonar total e do volume residual obtidos pelas técnicas pletismográfica e de respiração única com metano

 

Comparison between total lung capacity and residual volume values obtained by pletysmography and single breath methods with methane

 

Ricardo Marques Dias 1

Fernando Hauaji Chacur 2

Sonia Regina da Silva Carvalho 3

André Luís Mancini 4

Geraldo A Capuchino Jr 4

 

Resumo

Foram analisados exames de função pulmonar de 20 asmáticos, em acompanhamento no HU Gaffrée Guinle, classificados, segundo o Consenso Brasileiro (2002), em asma leve persistente ou moderada (9) e grave (11). Foram obtidos os valores dos parâmetros da espirografia, da pletismografia e da técnica de respiração única, com metano, para a medida da difusão pulmonar (DLco). Assim, a capacidade pulmonar total e o volume residual, quando medidos pela pletismografia, foram designados, respectivamente, CPTPL e VRPL. Da mesma forma, quando determinados pela técnica de respiração única, CPTSB e VRSB. A amostra foi constituída por 13 mulheres e 7 homens, sendo a média de idade de 47,6 anos. A intensidade da disfunção, medida pela relação VEMS/CVF foi de 58,8%, com IC95 de 53,9 a 63,6. Os valores de CPTPL (5,94) e VRPL (2,55), expressos em litros e pela média, foram significativamente maiores do que os de CPTSB (4,73) e VRSB (1,66). Foram determinadas equações de regressão múltipla, para previsão dos valores de CPTPL e VRPL, utilizando os valores de CPTSB, VRSB e dos parâmetros espirográficos, com coeficientes de regressão significativos. Contudo, a inclusão dos parâmetros espirográficos, excepto por CVF, não melhorou a capacidade de previsão das equações. Considerando apenas a CPTSB, r2=0,79, a equação é: CPTPL=(CPTSB*1,025)+1,088, com EP=0,64. A regressão para VRPL, com r2=0,23, é: VRPL=(VRSB*0,9268)+1,012. Os exames realizados após a broncodilatação, com 400mcg de salbutamol, não melhoraram as equações. Concluímos que a técnica de SB não dá resultados iguais aos da pletismografia para CPT e VR; contudo, para a CPT, esta diferença pode ser prevista.

Palavras-chave: Pletismografia de corpo inteiro, teste de difusão (DLCO), determinação dos volumes pulmonares, testes de função pulmonar, asma.

 

Abstract

We analyzed pulmonary function tests of twenty asthmatic patients from Gaffrée e Guinle University Hospital, classified according to Brazilian Guidelines for Asthma (2002), similar to GINA, into mild persistent or moderate (9) or severe (11) asthma. We obtained parameters from spirometry, plethysmograph(PL) and single breath technique for diffusion capacity (SB), with methane. Total lung capacity and residual volume were called TLCPL and RVPL when measured by pletysmography and TLCSB and RVSB when determined by single breath test. There were 13 women and 7 men with mean age of 47.6 years. The pulmonary dysfunction degree to FEV1/FVC was 58.8% with CI95=53.9 to 63.6. The mean values in litres for TLCPL (5.94) and RVPL (2.55) were significantly higher than for TLCSB (4.73) and RVSB (1.66). Multiple regression equations were determined for TLCPL e RVPL using only single breath values,TLCSB or RVSB, and spirographic parameters, with significant regression coefficients. However, the inclusion of spirometric parameters, except for FVC, did not improve the predicted capacity for the equations. Considering only the TLCSB, r2=0.79, the equation is: TLCPL=(TLCSB*1.025)+1.088, with EPE=0.64. The regression for RVPL, r2=0.23, is: RVPL=(RVSB*0.9268)+1.012. The results obtained after bronchodilation with 400 mcg of salbutamol did not improve the regression. We concluded that the SB technique did not obtain the same results as pletysmography for TLC and RV, but for TLC this difference can be predicted.

Key-words: Whole body pletysmography, pulmonary diffusion test (DLco), pulmonary volumes, pulmonary function tests, asthma.

 

Texto completo disponível apenas em PDF.

Full text only available in PDF format.

 

Bibliografia/Bibliography

1. American Thoracic Society. Epidemiology standardization project: recommended standardization procedure for pulmonary function testing. Am Rev Respir Dis 1978;118(Suppl 2):55-88.        [ Links ]

2. Sociedade Brasileira de Pneumologia e Tisiologia. III Consenso Brasileiro no Manejo da Asma. J Pneumol 2002;28(supl 1):S1-S28.

3. Global Initiatve for Asthma. Workshop Report, Global Strategy for Asthma Management and Prevention. Update 2005. www.ginasthma.com/

4. Sociedade Brasileira de Pneumologia e Tisiologia. I Consenso Brasileiro sobre Espirometria. J Pneumol, v. 22, n. 3, p. 105-164, 1996

5. Sociedade Brasileira de Pneumologia e Tisiologia. Diretrizes para Testes de Função Pulmonar. J Pneumol 2002;28 (supl 3):S1-S238.

6. ATS/ERS Task Force: Standardization of Lung Function Testing: Standardization of spirometry. Eur Respir J 2005;26:319-338.

7. ATS/ERS Task Force: Standardization of Lung Function Testing: Standardization of the measurement of lung volumes. Eur Respir J 2005;26:511-522.

8. ATS/ERS Task Force: Standardization of Lung Function Testing. Standardization of the single-breath determination of carbon monoxide uptake in the lung. Eur Respir J 2005;26:720-735.

9. ATS/ERS Task Force: Standardization of Lung Function Testing. Interpretative Strategies for Lung Function Tests. Eur Respir J 2005;26:948-968.

10. Knudson, R J, Lebowitz, M D, Holberg, C J, Burrows, B. Changes in the normal maximal expiratory flow volume curve with growth and aging. Am Rev Respir Dis, v. 127, p. 725-724, 1983.

11. Crapo RO, Morris AH. Standardized single breath normal values for carbon monoxide diffusing capacity. Am Rev Respir Dis 1981;123:185-9.

12. Crapo RO, Morris AH, Clayton PD. Lung volumes in healthy nonsmoking adults. Bull Eur Physiophatol Respir 1982; 18: 419-425.

13. GraphPad InStat version 3.01, Copyright 1992-1998 GraphPad Software Inc, San Diego California USA, www.graphpad.com

14. MedCalc Version 8.1.1.0 – © 1993-2005 Frank Schoonjans, http://www.medcalc.be/

15. Punjabi NM, David Shade BA, Wise RA. Correlation of a single-breath helium lung volumes in patients with air flow obstruction. Chest 1998;114:907-918.

 

1 Professor Titular da Disciplina de Pneumologia da UNIRIO, HU Gaffrée e Guinle / Titular Professor, Pulmonology, UNIRIO, Gaffrée e Guinle University Hospital.

2 Responsável pelo Serviço de Provas de Função Respiratória do Prócardiaco / Head of Prócardiaco Respiratory Function Unit.

3 Profa Adjunta da Disciplina Cardiopulmonar da UNIRIO, Responsável pelo Ambulatório de Asma / Associate Professor, Cardio-pulmonary, UNIRIO, Head of Asthma Out-Patients

4 Bolseiro de Iniciação Científica da UNIRIO / Scholarship holder, Science Initiation, UNIRIO.

* Trabalho realizado no HU Gaffrée e Guinle e no Hospital Prócardiaco / Work undertaken at Gaffrée e Guinle University Hospital and at the Prócardiaco Hospital.

 

Correspondência/Correspondence to: Laboratório de Função Pulmonar – Hospital Prócardiaco.

Rua Dona Mariana 219 CEP 22280-020 Botafogo RJ Rio de Janeiro Brasil

e-mail : pfr@procardiaco.com.br

 

Recebido para publicação/received for publication: 06.04.27

Aceite para publicação/accepted for publication: 06.07.21