SciELO - Scientific Electronic Library Online

 
vol.33 issue4Anticorrosive Properties of Chitosan for the Acid Corrosion of Aluminium author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Portugaliae Electrochimica Acta

Print version ISSN 0872-1904

Port. Electrochim. Acta vol.33 no.4 Coimbra July 2015

https://doi.org/10.4152/pea.201504241 

Chemical and Electrochemical Combined Processes to Treat Sanitary Landfill Leachates

A. Fernandes* , N. Afonso , J. Coelho , M. J. Pacheco , L. Ciriaco and A. Lopes

FibEnTech/MTP Unit and Department of Chemistry, University of Beira Interior, 6201-001 Covilha, Portugal

 

Abstract

The application of combined chemical coagulation and electrochemical oxidation processes to treat a leachate from an intermunicipal sanitary landfill was evaluated. Chemical coagulation (CC) experiments were performed with lime (Ca(OH)2), and the influence of the lime concentration, stirring speed and assay duration were studied. In the electrochemical oxidation (EO) assays, a boron-doped diamond anode was used, and two applied current intensities were tested. It was also evaluated the influence of the lime concentration used in the CC pre-treatment on the EO performance. In the CC assays, the highest COD removals were obtained for lime concentrations of 20 and 25 g L-1, at 100 rpm stirring speed, during 2 h. In the CC+EO combined treatment the highest removals were obtained at the applied current intensity of 0.6 A, being the influence of the lime concentration used in the pre-treatment almost insignificant. The highest current efficiency was obtained for the combined treatment with EO assays performed at 0.4 A.

Keywords: landfill leachate; chemical coagulation; lime concentration; electrochemical treatments; electrochemical oxidation; BDD.

 

Introduction

Huge amounts of solid wastes are being produced daily and the simplest procedure for their discharge, with low cost, is the deposition on sanitary landfills [1]. However, as a result of rainwater percolation through the wastes, a very complex effluent is produced, usually known as sanitary landfill leachate. This leachate composition is very complex and it may contain all type of organic and inorganic compounds, some of them refractory and toxic, and heavy metals [1,2]. Besides the organic matter, ammonia nitrogen is of great environmental concern in landfill leachates [3]. It is released from wastes mainly due to the decomposition of proteins and has been found in leachates at a concentration range from 0.2 to 13000 mg L-1 [4].

Nowadays, biological reactors, with nitrification/denitrification steps, followed by membrane technologies, are commonly used to treat leachates. However, due to the variability in the quality and quantity of the leachate throughout the life span of the treatment plant, these conventional treatments may become ineffective. Thus, it is very important to apply reliable and effective treatment technologies, capable of deal with such complex effluents.

Efficient methods for sanitary landfill leachates remediation based on electrochemical technologies are being developed. Among them, electrochemical oxidation (EO) is the most popular electrochemical procedure for removing organic pollutants from wastewaters, being boron-doped diamond (BDD) the most intensively studied anode material [5]. There are several papers describing the application of EO in sanitary landfill leachates, with promising results [3,610]. In fact, this treatment method has shown high potential to treat efficiently sanitary landfill leachates, although the high energetic costs are pointed as the main drawback to its full-scale implementation. EO integration with other treatment methods can be a possible solution to overcome this drawback. There are several reports describing the application of combined methods involving EO to treat sanitary landfill leachates [11-23]. A simple and economic process, widely used in wastewater treatment plants, is the chemical coagulation (CC). This process has shown to be efficient in the treatment of sanitary landfill leachates and has been widely used as a pre-treatment, prior to biological or reverse osmosis steps, or as a final polishing treatment step, in order to remove non-biodegradable organic matter [4]. The efficiency of the CC process depends on several factors, such as the nature and dosages of the coagulant, the characteristics of the leachate, the use of the process as a pre-treatment or posttreatment [4].

Several authors refer lime as the most used reagent in CC processes, being the amount required to treat sanitary landfill leachates between 1 to 15 g L-1 [24-27]. The main advantages of using lime in the CC process include its low cost, its availability in many countries and the fact that it does not contribute to increase salinity, as happens when aluminum or iron salts are employed.

According to Renou et al. [28], CC with lime acts preferentially in organic compounds of high molecular weight, such as humic acids present in stabilized leachates. Also, the CC treatment with lime eliminates most of the organic macromolecules in the first moments of the reaction, being almost 91% of the organic matter removed during the first 30 s and more than 99% removed at the end of a rapid mixing (5 min) [29].

The aim of this work was to evaluate the application of CC and EO as a combined treatment for a leachate from an intermunicipal sanitary landfill. The CC with lime was used as a first step, in order to remove colloidal and suspended particles, and it was followed by EO to eliminate the remaining dissolved persistent organic compounds. In the CC experiments, different added lime concentrations, stirring speed and assay durations were tested, in order to study their influence on the removal of the organic matter. In the EO assays, performed with a BDD anode, the influence of the applied current density and of the CC pre-treatment lime concentration, was studied.

 

Materials and methods

Leachate samples

The leachate samples used in this study were collected at a Portuguese intermunicipal sanitary landfill site, with an area of 1 km2 divided in 7 cells, being 6 of them sealed since 2012. Approximately 250 m3 of leachate are produced daily at this landfill facility (average value). Samples were collected in the stabilization lagoon, before being submitted to any treatment, and kept refrigerated, in order to maintain its initial characteristics. Samples characterization is presented in Table 1.

 

 

Analytical determinations

Degradation tests were followed by chemical oxygen demand (COD), biochemical oxygen demand (BOD5), dissolved organic carbon (DOC), dissolved inorganic carbon (DIC), total nitrogen (TN), total ammonia nitrogen (TAN) and total Kjeldahl nitrogen (TKN), which were performed according to standard procedures [30]. The COD determinations were made using the closed reflux titrimetric method. The BOD5 was evaluated by determining the oxygen consumption after 5 days of incubation. The DOC, DIC and TN were measured in a Shimadzu TOC-VCPH analyzer combined with a TNM-1 unit. Before DOC, DIC and TN determinations, samples were filtered through 1.2 μm glass microfiber filters. The TAN and TKN were determined using a Kjeldatherm block-digestion-system and a Vapodest 20s distillation system, both from Gerhardt. The pH was measured using a HANNA pH meter (HI 931400). The conductivity was determined using a Mettler Toledo conductivity meter (SevenEasy S30K).

Chemical coagulation and electrochemical oxidation assays

The CC experiments were performed in a Jar tester equipment (Lovibond, ET 730, portable floc tester), using 0.5 L of leachate. With the aim of optimizing experimental conditions, a first set of assays was performed, where the added lime concentration was 15 g L-1 and the stirring speed and assay duration were varied between 50-200 rpm and 1-4 h, respectively. Based on the results obtained in this first set of assays, a second set of CC assays was performed, where different lime concentrations between 10 and 25 g L-1 were tested, applying a stirring speed and assay duration of 100 rpm and 2.5 h, respectively.

All the CC experiments were conducted at room temperature (22-25 °C). After the CC treatment, the samples were centrifuged in a high frequency induction motor centrifuge (Meditronic BL-S), at 5000 rpm during 5 min, and the supernatant liquid was collected for the analytical determinations. For the first set of assays, only COD was determined.

In the combined treatment of CC+EO, the CC was performed using 20 and 25 g L-1 of lime and, after that, the centrifuged samples were subjected to the EO treatment.

The EO experiments were conducted in batch mode with stirring (100 rpm), during 6 h, at room temperature (22-25 °C) and using 200 mL of the coagulated effluent. A BDD anode and a stainless steel cathode, both with an area of 10 cm2, were used. The applied current intensities evaluated were 0.4 and 0.6 A. In the electrochemical experiments it was used a DC power supply GW, Lab DC, model GPS-3030D (0-30 V, 0-3 A).

Both CC and EO assays were performed, at least, in duplicate, and the values presented for the analytical parameters used to follow the assays are mean values.

 

Results and discussion

Fig. 1 presents the COD removals obtained for the chemical coagulation assays performed with different stirring speed and assay duration, at a lime concentration of 15 g L-1.

 

 

From the obtained results, it can be seen that stirring speed of 100 rpm promoted higher COD removals than stirring speed of 50 rpm. This can be due to the fact that when stirring is slow, lime stays deposited in the bottom of the beaker, and does not react efficiently with the leachate. However, when stirring speed was increased to 200 rpm, except for the assay with 1 h duration, a slight decrease in COD removals was observed when compared with the assays performed at 100 rpm, probably because excessive stirring inhibits the hydroxides action, being the formed flocks smaller and with less tendency to precipitate.

Regarding to assays duration, it can be seen from Fig. 1 that, around 2.5 h, there is a stabilization in the COD removal and longer assay duration does not lead to higher COD removal. Based on these results, to perform the CC assays the most suitable conditions were a duration of 2.5 h with a stirring speed of 100 rpm. Thus, in the subsequent assays performed to study the influence of the lime concentration, experiments were conducted at those experimental conditions.

Inset of Fig. 1 presents the COD removals obtained in the assays performed at 100 rpm stirring speed, during 2.5 h, with lime concentration varying from 10 to 25 g L-1. It can be observed that the best COD removals were obtained at 20 and 25 g L-1, with only a small difference between the removals obtained with these lime concentrations. Table 2 presents the results obtained for the CC assays performed with different lime concentrations.

 

 

As it can be seen, COD removal increased with the amount of lime added, achieving a COD removal of 43% when the lime concentration was 25 g L-1 . DOC removal was low when compared with DIC removal and presented its high values at lime concentrations of 20 and 25 g L-1. DIC removal was above 90% for all the lime concentrations tested, with no significant differences between them. All forms of nitrogen measured presented low removals, especially TAN, being the highest removal values obtained for lime concentrations of 20 and 25 g L-1 . Biodegradability index, measured by the ratio BOD5/COD, largely increased when compared to the initial sample, although this increase decreased with the amount of lime added. Thus, the best experimental conditions chosen to perform the CC pretreatment were: 20 and 25 g L-1 lime concentration; 2.5 h assay duration; stirring speed of 100 rpm. These optimized lime concentrations are higher than those usually found in literature [24-27]. This can be due to the different characteristics of the sanitary landfill leachate used.

The results of the EO experiments performed with samples pre-treated with CC are shown in Fig. 2 and in Table 3.

 

 

 

From Fig. 2, it can be seen that COD removal is more influenced by the current intensity applied in the EO process than by the lime concentration added in the CC pre-treatment.

Fig. 2 also includes the COD theoretical decay, calculated for the two current intensities, using Eq. (1),

 

 

where COD0 and CODt are the initial COD and COD at time t, in mg L-1, I is the current intensity, in A, F is the Faraday constant, 96485 C moL-1, V is the solution volume, in m3, and t is the time, in s. From the theoretical lines, it can be inferred that the current efficiency decreases with the increase of current intensity, since the deviation between theoretical and experimental curves is higher for the assay run at the highest applied current intensity.

DOC and TN removals present a similar behaviour to that of COD (Table 3). Regarding TKN and TAN parameters, they present higher removals than TN, indicating that nitrates are still present in solution at the end of the assays. For all the conditions tested, TKN and TAN removals in the combined treatment were around 100%.

During the EO process, the pH returned to its original value and the conductivity values dropped drastically, which can be attributed to the formation of carboxylic acids during the oxidation of the organic matter, and to the deposition on the cathode surface of reduced ionic species, respectively.

 

Conclusions

According to the obtained results, the application of combined chemical coagulation and electrochemical oxidation seems feasible for the treatment of leachates from sanitary landfills. The addition of lime promotes good COD removals, although the removals of the different nitrogen forms are small, particularly for the total ammonia nitrogen. Also, an increase in the biodegradability is noticed by the addition of lime.

EO treatment, using pre-treated leachate by CC with lime, results in high COD removals and complete TKN and TAN removals.

Attending to the lime consumption and the energy costs with stirring, during the CC pre-treatment, and with the EO process, the most favorable conditions found for the combined treatment were CC with 20 g L-1 of lime at 100 rpm stirring speed, during 2.5 h, followed by EO at 0.4 A, during 6 h.

 

References

1. Eggen T, Moeder M, Arukwe A. Sci Total Environ. 2010;408:5147.         [ Links ]

2. Oman CB, Junestedt C. Waste Manage. 2008;28:1876.         [ Links ]

3. Deng Y, Englehardt J D. Waste Manage. 2007;27:380.         [ Links ]

4. Renou S, Givaudan J G, Poulain S, et al. J Hazard Mater. 2008;150:468.         [ Links ]

5. Martinez-Huitle C A, Brillas E. Appl Catal B: Environ. 2009;87:105.         [ Links ]

6. Cossu R, Polcaro A, Lavagnolo M, et al. Environ Sci Technol. 1998;32:3570.         [ Links ]

7. Cabeza A, Urtiaga A, Ortiz I. Ind Eng Chem Res. 2007;46:1439.         [ Links ]

8. Anglada A, Urtiaga A, Ortiz I. J Hazard Mater. 2010;181:729.         [ Links ]

9. Fernandes A, Pacheco M J, Ciriaco L, et al. J Hazard Mater. 2012;199200:82.         [ Links ]

10. Fernandes A, Pacheco M J, Ciriaco L, et al. Appl Catal B: Environ. 2015;176:183.         [ Links ]

11. Wang P, Lau I W C, Fang H H P. Environ Technol. 2001;22:373.         [ Links ]

12. Ihara I, Kanamura K, Shimada E, et al. IEEE Transactions on Applied Superconductivity 2004;14:1558.         [ Links ]

13. Lei Y, Shen Z, Huang R, et al. Water Res. 2007;41:2417.         [ Links ]

14. Feki F, Aloui F, Feki M, et al. Chemosphere 2009;75:256.         [ Links ]

15. Papastavrou C, Mantzavinos D, Diamadopoulos E. Environ Technol. 2009;30:1547.         [ Links ]

16. Urtiaga A, Rueda A, Anglada A, et al. J Hazard Mater. 2009;166:1530.         [ Links ]

17. Zhao X, Qu J, Liu H, et al. Bioresour. Technol. 2010;101:865.         [ Links ]

18. Norma D, Fernandes A, Pacheco MJ, et al. Port Electrochim Acta. 2012;30:221.

19. Norma D, Fernandes A, Ciriaco L, et al. Port Electrochim Acta. 2012;30:281.         [ Links ]

20. Orkun M O, Kuleyin A. Environ Prog Sust Energy. 2012;31:59.         [ Links ]

21. Garaj-Vrhovac V, Orescanin V, Gajski G, et al. Chemosphere. 2013;93:939.         [ Links ]

22. Xiao S, Peng J, Song Y, et al. Sep Purif Technol. 2013;117:24.         [ Links ]

23. Fernandes A, Spranger P, Fonseca A D, et al. Appl. Catal. B: Environ. 2014;144:514.         [ Links ]

24. Thornton RJ, Blanc FC. J Environ Eng Div. 1973;99:535.         [ Links ]

25. Ho S, Boyle C W, Ham R K. Water Pollution Control Federation 1974;46:1776.         [ Links ]

26. Keenan J D, Steiner R L, Fungaroli A A. J Environ Eng. 1983;109:1371.         [ Links ]

27. Slater C S, Ahlert, R C, Uchrin C G. Environ Prog. 1983;2:251.         [ Links ]

28. Renou S, Poulain S, Givaudan J G, et al. J Membr Sci. 2008;313:9.         [ Links ]

29. Renou S, Poulain S, Givaudan J G, et al. Water Sci Technol. 2009;59:673.         [ Links ]

30. Eaton A, Clesceri L, Rice E, et al. Standard methods for examination of water and wastewater. 21st ed. Washington, DC: American Public Health Association; 2005.         [ Links ]

 

Acknowledgements

The authors gratefully acknowledge the financial support received from FCT, for the funding of the FibEnTech Research Unit, through ''Financiamento agregado para o bienio 2015-2016'', project UID/Multi/00195/2013, and for the grant awarded to A. Fernandes, SFRH/BPD/103615/2014.

 

*Corresponding author. E-mail address: annabelf@ubi.pt

Received 23 June 2015; accepted 27 August 2015

www.peacta.org

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License